When the User Name is set, press button E to di-
splay the choice of the function related to SAFETY
or TEA2 actuator.
If you want to modify the parameter act on buttons
A (+) or B (-); 0000 will mean that you have chosen
to use SIC/EVTEA2 relay as EVTEAS2, 0001 will
mean that you have chosen to use SIC/EVTEA2
actuator as SAFETY.
To display the next parameter, i.e. LEVEL TIME-
OUT, just press button E (MENU).
If you want to modify the Level Time-out parameter,
press buttons A (+) or B (-) to increase or decrease
its value.
When Time-out has been programmed, to go
to the next menu press E (MENU) and LITRES
PROGRAMMING will be displayed for setting.
If you want to modify the “water filter “ parameter
related to the litres calculated, press buttons A (+)
or B (-) to increase or decrease its value.
When LITRES parameter has been programmed,
go to the next parameter by pressing E (MENU) for
the setting of the type of PUSH BUTTON PANEL
used on dosing and this will apply to all push button
panels used for the three groups.
Select “Esp – Cof – 2Es – 2Cof
Press E to display the setting of ON times of so-
lenoid valve EVx during PRE-INFUSION.
The first programmable ON time is related to but-
tons A of each group.
If you want to modify the ON parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion ON
time on buttons A of each group, press button E
(MENU) to go to the setting of pre-infusion ON
time of B buttons of each group.
If you want to modify the ON parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion ON
time on buttons B of each group, press button E
(MENU) to go to the setting of pre-infusion ON
time of C buttons of each group.
If you want to modify the ON parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion ON
time on buttons C of each group, press button E
(MENU) to go to the setting of pre-infusion ON
time of D buttons of each group.
If you want to modify the ON parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion ON
time on buttons D of each group, press button E
(MENU); to display the new programmable para-
meter, i.e. the setting of OFF times of solenoid
valve Evx during PRE-INFUSION starting from
buttons A of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion OFF
time on buttons A of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of B buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion OFF
time on buttons B of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of C buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion OFF
time on buttons C of each group, press button E
(MENU) to go to the setting of pre-infusion OFF
time of D buttons of each group.
If you want to modify the OFF parameter act on
buttons A (+) or B (-) to increase or decrease its
value.
At the end of the programming of pre-infusion OFF
time on buttons D of each group, press button E
(MENU.)
Now there is the possibility of really enabling or
disabling the pre-infusion function during dispen-
sings.
If you want to modify the pre-infusion enabling/di-
sabling parameter, act on buttons A (+) or B (-);
0000 means that you have chosen not to use the
pre-infusion functions during dispensings, while
0001 means that you have chosen to use it.
When you have chosen to enable or disable the
pre-infusion function during dispensing, if button
E (MENU) is pressed, the system will go to idle-
on status and TECHNICAL PROGRAMMING will
therefore be terminated.
Note: After accessing the TECHNICAL PROGRAM
-
MING environment, if you want to exit you shall scroll
all menus by pressing button E (MENU) until you go
back to idle on status (Select Drink) ; no automatic
exit time-out from technical programming phase is
provided.
75